Extensive multiplanar locking options

The TN-ADVANCED™ Tibial Nailing System Nail is designed to provide stability in simple to complex fracture cases, particularly in cases with short metaphyseal fracture fragments or osteoporotic bone.1,2

14 mm

20 mm

30 mm

36 mm

43 mm

57 mm

37 mm

22 mm

13 mm

5 mm

Rounded tips

for less prominence, designed to reduce soft tissue irritation 3,4

Optional Low Profile Screw

Low profile design reduces likelihood of pain and soft tissue irritation related to implant prominence 3,4

27% increase in bone purchase

compared to conventional EXPERT NAIL™ Locking Screws.3

Locking screws improve anchorage in the near cortex through an increased thread diameter.3

Most distal screw 5mm from tip

The most distal screw offers choice of 30° lateral or medial angulation for multiplanar locking while avoiding vital anatomy​.5

Angular Stability in all Screw Holes with no Extra Steps2, 6

Polymer inlay reduces toggle by up to 72% compared to a conventional nail without polymer inlay such as the EXPERT NAIL™ Tibial Nail.2

QUICK CLICK™

Self-Retaining Technology for facilitated attachment of the nail to the insertion handle.7

QUICK CLICK™

Self-Retaining Technology for facilitated attachment of the nail to the insertion handle.7

Instrument features designed to save time through ease of use.8

The thin multi-hole wire guide was designed to allow controlled insertion of a guide wire before suprapatellar sleeve insertions.7

Compressible sleeve

reduces pressure on the patello-femoral joint (PFJ) by up to 70% compared to solid sleeve design.9

QUICK CONNECT LATCH

for fast assembly and disassembly saves time in the OR compared to a threaded connection.8

TWIST & LOCK

Protection sleeves secured in the aiming arm with one quarter twist.10

1.DePuy Synthes Instructions For Use for TN-ADVANCED™ Tibial Nailing System. 8/2020. Package Insert GP3114-A / Agile Document # SE_793150.
2.DePuy Synthes biomechanical test report for TN-ADVANCED™ Tibial Nailing System Nail. 8/13/2020. Windchill Document #0000305118
3.DePuy Synthes test result summary for Secure Retaining Screws. 8/17/2020. Windchill Document #0000295306
4.Katsoulis E, Court-Brown C, Giannoudis PV. Incidence and aetiology of anterior knee pain after intramedullary nailing of the femur and tibia. J Bone Joint Surg Br. 2006 May;88(5):576-80. doi: 10.1302/0301-620X.88B5.16875. PMID: 16645100.
5. DePuy Synthes evaluation of distal locking screw pattern in tibial nails. 8/20/2020. Windchill Document #0000306152
6. DePuy Synthes description of locking polymer in TN-ADVANCED™ Tibial Nailing System Nail. 8/17/2020. Windchill Document #0000305648
7. DePuy Synthes design validation report for TN-ADVANCED™ Tibial Nailing System System. 7/16/2020. Windchill Document #0000294357
8. DePuy Synthes usability evaluation for TN-ADVANCED™ Tibial Nailing System Instrumentation. 8/18/2020. Windchill Document #0000305666
9. DePuy Synthes contact pressure test report for suprapatellar protection sleeve. 8/17/2020. Windchill Document #0000305720
10. DePuy Synthes Advanced Nails System Summary. 7/25/2020. Windchill Document #0000302373

Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions. Not all products are currently available in all markets. CAUTION: Federal Law restricts these devices to sale by or on the order of a physician. 165884-210129 DSUS/EMEA © DePuy Synthes 2022. All rights reserved.